Annals of African Medicine
Home About AAM Editorial board Ahead of print Current Issue Archives Instructions Subscribe Contact us Search Login 
RESEARCH ARTICLE
Year : 2007  |  Volume : 6  |  Issue : 1  |  Page : 31-33

Surgical hand scrub: Lots of water wasted


Department of Surgery, Ahmadu Bello University Teaching Hospital, Zaria, Nigeria

Correspondence Address:
A Ahmed
Department of Surgery, Ahmadu Bello University Teaching Hospital, Zaria
Nigeria
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1596-3519.55733

Rights and Permissions

Background : Surgical hand scrub (SHS) is an important antisepsis measure before participating in surgical operation. It reduces the risk of microbial contamination of the surgical wound by skin flora. SHS is usually performed in a scrub sink with taps that have hand operated handles. During the scrub process large volume of water is wasted. The aim of this study was to determine the volume of water used during SHS in comparison to the actual volume necessary. Method : Unknown to them various cadreof the operation team were timed during their first scrubbing of the day for scheduled operations. Duration of scrubbing (ST) and that during which the hands were being washed with flowing water (WT) were recorded. The amount of water flowing through the tap per minute was also recorded. Using the mean ST, WT and water flow per minute the total volume of water used during scrubbing and that necessary to wash the hand were calculated. Results : Overall, the ST ranged between 3 and 7 minutes with a mean of 4.8 ± 0.5 SD minutes. Mean WT was 1.4 ± 0.4 SD minutes. The mean water flow was 4,217mls per minutes. The volume of water used per scrubbing was 20.2 litres while only 5.9 litres was used for washing the hands. Between January and December 2002, the volume of water used for scrubbing was 200,283 litres while only 58,498.5 litres (29.2%) was necessary. Conclusion : Plenty water is wasted during SHS. Reducing the amount of water flowing unused would provide cost saving to the hospital. The use of taps operated with foot pedal would reduce the waste.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3877    
    Printed197    
    Emailed7    
    PDF Downloaded90    
    Comments [Add]    
    Cited by others 7    

Recommend this journal